Customization: | Available |
---|---|
Capacity: | 1-2 People, 1-2 People |
Drain Placement: | Corner, Corner |
Still deciding? Get samples of US$ 433.79/Piece
Order Sample
|
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Compant Name: Foshan Nanhai Dewo Sanitary Ware Co., Ltd.
Time of Establishment: 6th January 2005
Company Address: Xiaotang Xinjing Industrial Zone, Nanhai District, Foshan City, Guangdong Province, China
DEWO has been 20 years since its inception in 2005.
Over the past 20 years, DEWO has been insisting on creating high-quality and high-level bathroom space, and has a very good reputation in the industry.
After 20 years of precipitation and development, we have mastered a variety of bathroom development technology to meet the needs of customers to sample customization and personalized customization.
Configuration materials | Acrylic, massage nozzles, faucets, dehydrators, etc |
Function | Cold and hot water inlet faucets, massage surfing, pipeline water inlet cleaning, leakage protection, colorful atmosphere lights, etc |
Design philosophy | LL750 is a popular star product from Dewo, and the two person three-dimensional interlocking seat design optimizes the bathing space, providing ultra-high comfort and spaciousness for family bathing needs. The skirt features a concave design that blends aluminum and acrylic elements, fully embodying the beauty of geometry. The massage nozzle with a 360 ° surround angle provides a comprehensive bathroom experience for the body. The massage water circulation system soothes various parts of the body while also meeting the user's water-saving requirements. |
What is the warranty period for Dewo bathroom products? Bathtub: Within one year from the date of purchase, if a malfunction occurs during use due to quality issues with the Dewo bathtub, under proper installation, use, and maintenance, Dewo can communicate with the customer and choose to repair or replace the faulty parts of the product free of charge according to the actual situation. (The replaced faulty parts belong to DEWO Company) Bathtub accessories: Within one year from the date of purchase, if there is a malfunction during use due to quality issues with the Dewo bathtub accessories, under correct installation, use, and maintenance, Dewo can communicate with the customer and choose to repair or replace the faulty parts of the product for free according to the actual situation. (The replaced faulty parts belong to DEWO Company) |
Do we need to place something at the bottom of the bathtub while installing? Dewo's bathtub is composed of 3mm thick acrylic and 3mm thick fiberglass layer, making the bathtub as thick as 6mm, sturdy and durable. All Dewo bathtubs require no padding at the bottom, just a flat installation ground. |
How to install Dewo's bathtub? Ground wire (attached figure): Ground wire is used to prevent static electricity from occurring. You can fix the ground wire with screws or place it directly on the ground. Massage bathtub plug (attached picture): Connect the power directly to the corresponding position of the plug, and the massage function, constant temperature function, etc. of the bathtub can be used normally when the water level is sufficient. Cold and hot water pipes (attached diagram): In order to avoid the risk of use caused by water pressure differences, customers need to purchase cold and hot water pipes ( Standard Size: 16 pipe double head net pipe+4mm internal teeth, if there are special requirements, please explain before placing an order and purchase according to your actual needs. ) from local hardware stores or online stores. The installation instructions are as follows: Connect a cold water pipe to the interface below the faucet marked with cold water (blue) color, and connect the cold water pipe to the cold water faucet. The interface below the faucet marked with hot water (red) color is connected to a hot water pipe, and the hot water pipe is connected to a hot water faucet. Sewer and drain pipe (attached figure): Insert the drainage pipe directly into the floor drain hole. |
How to clean and maintain Dewo's bathtub products? Drainage plug cleaning: Remove the drainage plug, remove dirt and hair, and use a toothbrush to clean the scale that blocks the filter.
Bath wall cleaning: After taking a bath, clean the dirt with hot water, rinse with cold water to dissipate heat, and dry the water droplets. For stubborn dirt, cover it with a tissue, spray a neutral detergent, wait for 10-20 minutes, then lift the tissue and scrub with a sponge brush. Or pour in white vinegar and warm water mixed with dishwashing detergent, wipe with a cotton cloth, and rinse with clean water within 5 minutes. Attention: If there are water stains, try to wipe them dry in a timely manner. It is recommended to clean them once every 1-2 weeks.
Massage bathtub maintenance and upkeep: If the massage function is not used for a long time, it should be operated at regular intervals. Regularly clean the filter to prevent weakened massage water flow and malfunction of the circulation system.
Usage taboo: Please do not directly pour hot water above 80 degrees into the bathtub to avoid damaging the cylinder body. High temperature items such as lit cigarette butts should not be placed directly on the bathtub. Hard objects should be avoided from directly hitting the surface of the product, which may cause damage to the bathtub. If a bath detergent is used during bathing, the bathtub should be rinsed clean with water and wiped dry after use.
Attention: If groundwater or hot spring water is used, or indoor bathtubs are left exposed to sunlight and rain outdoors, it will cause discoloration on the surface of acrylic bathtubs and may shorten the service life of the product. |
Faucet accessories: 1. Daily care: Wipe clean immediately after regular use, often use a sponge dipped in cleaning agent to wipe, rinse with water, and then wipe clean with a dry cloth. 2. Cleaning of buried areas: If there is scale or rust on the buried area, it can be wiped off with a sponge, covered with a tissue, and sprayed with neutral detergent. Wait for 10-20 minutes before cleaning. 3. Cleaning of scale and oil on the surface of the faucet: Gently wipe with a soft bristled toothbrush or cleaning cloth dipped in toothpaste to remove scale and oil, making the surface of the faucet clean and shiny. Do not use strong acid or alkaline cleaning agents for product cleaning, and do not use abrasive cloths to wipe, otherwise it will damage the surface of the product. 4. Anti freezing measures: When the ambient temperature is below 0 degrees, the product should be kept warm or the residual water inside the product should be discharged to avoid product freezing. |
Is the bathtub drain not draining or draining slowly? It may be caused by clogged hair or pipes in the drain. You can try lifting the drain cover and using pointed pliers or tweezers to remove the hair. If the pipeline is blocked, please contact relevant personnel for handling. |
The bathtub massage function cannot be activated? Perhaps due to insufficient water level, it is possible to continue adding water until the water level exceeds the massage hole by 5-8cm. |
How to clean and maintain Dewo's shower room products? 1. Cleaning and usage taboos: Do not use strong acid or alkaline products (such as toilet cleaners) to clean glass, otherwise it will cause corrosion on the surface of chrome plated parts. Do not use steel wire balls or brushes to clean the glass surface. Do not use sharp objects to directly contact the surface of glass and hardware, otherwise scratches may occur. Do not lean against the shower room glass or hang other heavy objects on the shower room profile, otherwise it is easy to cause deformation of the profile, and the movement of the pulley or hinge is not smooth. 2. Cleaning precautions: Due to water quality reasons, yellow spots may be left on the surfaces of glass, hardware, and stone bases. Please use a soft cloth with detergent, white vinegar, and salt to add to warm water for cleaning; Or use universal cleaning cream, glass water, and a soft cloth to scrub. 3. Pulley maintenance;:Lubricating oil should be regularly added to the pulleys and hinges to prevent jamming or abnormal noise when the pulleys slide or the hinges move. 4. Light opening and closing: When opening and closing the door, it should be opened and closed gently. Do not use force to open or close the door. |
What should I do if the pulley derails when sliding the door glass? It may be caused by the screw on the upper pulley not being adjusted properly. You can try using a Phillips screwdriver to adjust the tightness of the upper pulley. |
What should I do if there is a gap between the hinge and the glass when opening and closing the door? It may be caused by loose locking screws, and you can try tightening the screws. |
How to clean the glass with stains and slight scale? It may be caused by water quality issues or prolonged lack of cleaning. A soft cloth can be used with detergent, white vinegar, and salt added to warm water for cleaning. |
More to updates... |